42

&X2

Selects slave receive timing. The modem derives the transmit
clock signal from the incoming carrier and applies it to the
TXCLK output at the serial interface

Command:

&Y

n

Select Profile for Hard Reset

Values:

n = 0 or 1

Default:

None

Description:

&Y0

Select profile 0 to be loaded on power-up.

&Y1

Select profile 1 to be loaded on power-up.

Note:

See also the &W and Z commands.

Command:

&Zy

=x Store Telephone Number

Values:

y = 0–3
x = Dialing command

Default:

None

Description:

Stores telephone dial string x in memory location y. Each tele-
phone number dial string can contain up to 30 digits. Dial the
stored number using the DS=y command.

Note:

DTR dialing uses the number stored in memory location 3.

Command:

%C

n Data Compression Control

Values:

n = 0, 1, 2, or 3

Default:

3

Description:

Enables or disables data compression negotiation. The modem
can only perform data compression on an error-corrected link.

%C0 Disables data compression.
%C1 Enables MNP 5 data compression negotiation.
%C2 Enables V.42bis data compression negotiation.
%C3 Enables both V.42bis and MNP 5 data compression negotiation.

Command:

%E

n Line Quality Monitor

Values:

n = 0, 1, or 2

Default:

2

Description:

Controls whether or not the modem will automatically moni-
tor the line quality and request a retrain (%E1) or fall back to a
lower speed when line quality is insufficient and fall forward
to a faster speed when line quality is sufficient (%E2).

%E0

Disable line quality monitor and auto-retrain.

%E1

Enable line quality monitor and auto-retrain.

%E2

Enable line quality monitor and fallback/fall forward.

Command:

%L

Line Signal Level

Values:

None

Default:

None

Description:

%L

Returns a value that indicates the received signal level in dBm.
The value returned is a direct indication (DAA-dependent) of
the receive level at the MDP, not at the telephone line connector.
Examples: 009 = -9 dBm, 043 = -43 dBm, and so on.