OM-1500-7 Page 27

Reset To Factory Settings
A reset menu is displayed if the following four

push buttons are pressed simultaneously:

Program, Sequence, upper display, and Set-

up. The upper display indicates “WIPE” . The

lower display indicates “OFF”. The lower

push button is active indicating that the Adjust

control can be used to change the unit to

“WIPE ON”. When “WIPE ON” is set, if the ori-

ginal four push buttons are simultaneously

pressed a second time, the unit will reset all

settings to factory default except the arc time

and arc cycle counts. If a reset is not desired,

set the display to “WIPE OFF” and simulta-

neously press the Program, Sequence, upper

display, and Setup push buttons to exit the re-

set menu.
Auxiliary Menu

An auxiliary menu is provided if both the Se-

quence and Setup push buttons are

pressed simultaneously. The Setup push

button and sequence push button LEDS

flash when the auxiliary menu is displayed.

Pushing the Setup push button will step

through the menu. Pushing the sequence

push button will step through the menu in re-

verse.

.

The auxiliary menu may be exited at any
time by pressing both the Sequence push

button and the Setup push buttons simul-

taneously.

V-Min And V-Max

If the Setup push button is pressed, the unit

allows the setting of the manual override

power source min and max voltage preset

range. The minimum voltage is displayed in

the upper display and the lower display indi-

cates “VMIN”. When the Setup push button

is pressed the unit displays the maximum

voltage setting of the welding power

source. The maximum voltage is displayed

in the upper display and the lower display

indicates “VMAX”.

In both cases, the Adjust control is used to

specify the minimum and maximum voltage

settings of the welding power source. The

settings correspond to arc voltage obtained at

minimum command and arc voltage obtained

at maximum command.
This method of setting “VMIN” and “VMAX”

may be used if the power source being used

is not listed in the Power Source Selection

Menu.

.

If a default power source has already
been selected with the Power Source

Selection menu, setting “VMIN” and

“VMAX” will override the default power

source settings.

.

The power source selection menu must
be set to “OFF” when overriding the de-

fault “VMIN” or “VMAX” settings.

Power Source Selection Menu

If the Setup push button is pressed, the unit

allows the Power Source Selection menu to

be disabled or enabled.

The upper display shows “PSS”. Lower dis-

play shows “On” or “Off”. The Adjust Control

is used to select either “On” or “Off”.
Arc Time

If the Setup push button is pressed, the unit

displays arc time in hours.

Arc time is indicated by the Program display

showing “HR”. Arc time is shown in the lower

display.
Cycles

If the Setup push button is pressed, the unit

displays the number of cycles.

Arc cycles are indicated by the Program dis-

play showing “CL”. The arc cycle count is

shown in the lower display.
Run-In

If the Setup button is pressed, the unit al-

lows setting the run-in modes. The run-in

modes are program specific. Each program

may be set to its own run-in mode.

The upper display indicates “RUNI”. The

lower display indicates “AUTO”, meaning

the factory set automatic run-in speed is

selected.
Pressing the lower display button allows a

manual setting the run-in wire speed. Speed

may be adjusted from 10% to 100% of weld

wire speed.
Pressing the lower display button allows

disabling of the run-in feature. When the

lower display indicates “OFF” run-in is dis-

abled.
Burnback

If the Setup push button is pressed, the unit

allows burnback time to be set.

Burnback time and voltage can be specified

when the lower display indicates “BURN” and

the upper display indicates the burnback time

or voltage. The Adjust control is used to set

the desired burnback time or voltage. Burn-

back settings, like run-in settings, are pro-

gram specific. The active program is dis-

played in the Program display and can be ad-

justed (see Section 6-6).
Trigger Hold Setup

If the Setup push button is pressed, the unit

allows trigger hold delay time to be set.

Trigger hold delay time is indicated by

”HOLD” in the lower display and the hold

delay time in the upper display. The adjust

control can be used to specify a new delay

time for trigger hold. Trigger hold delay time is

the minimum amount of time the trigger must

be held for trigger hold to work when the trig-

ger is released (the trigger hold function must

be on). For example, if a trigger hold delay

time of 2.0 seconds is defined, the operator

must hold the trigger for at least 2 seconds be-

fore releasing it in order for the trigger hold

function to work. Once the trigger hold func-

tion is in effect, the wire feeder will stay On un-

til the trigger is pressed and released again.

There is an additional function built in called

”maximum trigger hold time” which is the

maximum length of time the trigger can be

held and the trigger hold function still work

when the trigger is released (the trigger

hold function must be on). The maximum

trigger hold time is set at 4.0 seconds after

the trigger hold delay time. For example, if

a trigger hold delay time of 2.0 seconds is

defined, and the operator held the trigger in

for more than 6.0 seconds, the trigger hold

function would not be in effect and the wire

feeder would stop when the trigger is rele-

ased.

When the Setup push button is pressed

again, the menu repeats to the first menu

selection of run-in wire speed selection.

Trigger Program Select

If the Setup push button is pressed, the unit

allows Trigger Program Select or Trigger

Dual Schedule to be enabled or disabled.

The upper display shows “TSEL”. Lower dis-

play shows “OFF” or “PROG” or “DUAL”. The

Adjust Control is used to select “OFF” or

“PROG” or “DUAL”.
Trigger Program Select (PROG) allows the

operator to select programs during preflow by

clicking the trigger (pulling and releasing the

trigger in a maximum of 0.2 seconds). The

feeder will switch between any programs that

have a minimum of 0.2 seconds of preflow

time set in the weld sequence. Any combina-

tion of programs may be used. Trigger Pro-

gram Select cannot be used while welding or

with Dual Schedule.

(Example: If programs 1 and 3 have a mini-

mum of 0.2 seconds of preflow time, clicking

the trigger will toggle between programs 1

and 3).
Trigger Dual Schedule Select (DUAL) allows

the operator to switch between paired sched-

ules (programs 1−2, 3−4, 5−6, or 7−8) with the

gun trigger, but only while welding. This fea-

ture cannot be used with Trigger Hold or Dual

Schedule. To end the weld, the trigger must

be released for 0.4 seconds.

(Example: when welding with this feature en-

abled in program 1, if you release, re-trigger,

and hold again within <0.4 seconds, the ac-

tive program will switch to program 2. If the

previous sequence is repeated the active pro-

gram will switch back to program 1. This cycle

can be repeated for the entire weld).
Process Select
Process selection indicated by ”PROS” in the

upper display is set to either ”VOLT” or

”TRIM” in the lower display. Each program

can be selected be be a MIG program indi-

cated by ”VOLT” or a pulsing program indi-

cated by ”TRIM”.
Range Locks
Range locks are indicated by “LOCK” in the

upper display for wire speed or “LOCK” in the

lower display for voltage range. In a MIG pro-

gram, the voltage range lock ranges from 0 to

10 volts. In a pulse program, the trim range

lock ranges from 0 to 100. The wire feed

speed range lock ranges from 0 to 250 ipm.

Locks are program dependent and wire

speed is independent from voltage or trim.
Wire Feed Speed Units
Wire feed speed setting indicated by “WFS”

in the upper display is set to “IPM” inches−

per−minute or ”MPM” meters−per−minute.

This setting is independent of the program se-

lected.

6-12 Auxiliary Menus (Continued)