Section 4 − installation, 1. specifications, 2. duty cycle and overheating – Miller Electric NT 450 User Manual

Page 17

Advertising
background image

OM-2252 Page 13

SECTION 4 − INSTALLATION

4-1. Specifications

Model

Rated

Welding

Amperage/

Voltage Range

Max OCV−DC

Amperes Input at Rated Load Output 50/60 Hz,

Three-Phase

Model

Welding

Output

Voltage Range

Max OCV−DC

230 V

380 V

400 V

440 V

460 V

575 V

KVA

KW

450 Amp

450 A @ 38

Volts DC 100%

5 − 500A In CC

Mode

78 VDC In

CC Mode For

60 Hz

80 VDC In CC

Mode For 50 Hz

57

34

33

30

29

23

22.6

21.0

450 Amp Volts DC, 100%

Duty Cycle

10 − 38V In CV

Mode

78 VDC In

CV Mode For

60 Hz

80 VDC In CV

Mode For 50 Hz

*2.18

*1.11

*1.05

*.950

*1.04

*0.84

*0.87

*0.29

*While idling

4-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-

utes that unit can weld at rated load

without overheating.
If unit overheats, thermostat(s)

opens, output stops, and cooling

fan runs. Wait fifteen minutes for

unit to cool. Reduce amperage or

duty cycle before welding.
NOTICE − Exceeding duty cycle

can damage unit and void warranty.

100% Duty Cycle

Overheating

0

15

A/V

OR

Reduce Duty Cycle

Minutes

duty1 4/95 / 210 976-B

Continuous Welding

Advertising