Certain modem values, or parameters, are stored in memory locations called S-registers. Use the S
command to read or to alter the contents of S-registers (see previous section).

Register

Unit

Range

Default

Description

S0

1 ring

0, 1–255

1

Sets the number of rings until the modem
answers. ATS0=0 disables autoanswer completely.

S1

1 ring

0–255

0

Counts the rings that have occurred.

S2

decimal

0–127

43 (+)

Sets ASCII code for the escape sequence

128–255

character. Values greater than 127 disable

escape.

S3

decimal

0–127

13 (^M)

Sets the ASCII code for the carriage return

character.

S4

decimal

0–127

10 (^J)

Sets the ASCII code for the line feed

character.

S5

decimal

0–32

8 (^H)

Sets the ASCII code for the backspace

33–127

character. Values greater than 32 disable

backspace.

S6

seconds 2–65*

2*

Sets the time the modem waits after it goes

off-hook before it begins to dial the telephone
number.

S7

seconds 1–255*

50*

Sets the time the modem waits for a carrier

signal before aborting a call. Also sets the wait
for silence time for the @ dial modifier.

S8

seconds 0–65

2

Sets the length of a pause caused by a
comma character in a dialing command.

S9

decimal

0, 1–127 37 (%)

Sets ASCII code for remote configuration
escape character. S9=0 disables remote
configuration.

S10

100 ms

1–254

20

Sets how long a carrier signal must be lost
before the modem disconnects.

S11

1 ms

50–150* 95*

Sets spacing and duration of dialing tones.

S18

1 ms

0–255

20

Sets duration of time from the time the carrier

signal goes low and then goes high again as
set up by the &C2 command.

S28

decimal

0, 1–255 1

0 disables, 1–255 enables V.34 modulation.

S30

1 minute 0, 1–255 0

Sets the length of time that the modem waits
before disconnecting when no data is sent or
received. A value of zero disables the timer.
See also the \T command.

S35

decimal

0–1

0

0 disables, 1 enables the V.25 data calling
tone, which allows remote data/fax/voice
discrimination.

S36

decimal

0–7

7

Specifies the action to take in the event of a

negotiation failure when error control is
selected. (See S48.)