Chapter 3 - AT Commands, S-Registers and Result Codes

Register

Unit

Range

Default

Description

S37

decimal

0–19

0

Sets the maximum V.34 “upstream” speed at

which the modem attempts to connect.

0 = maximum modem speed
1 = reserved
2 = 1200/75 bps
3 = 300 bps
4 = reserved
5 = 1200 bps
6 = 2400 bps
7 = 4800 bps
8 = 7200 bps
9 = 9600 bps
10 = 12000 bps
11 = 14400 bps
12 = 16800 bps
13 = 19200 bps
14 = 21600 bps
15 = 24000 bps
16 = 26400 bps
17 = 28800 bps
18 = 31200 bps
19 = 33600 bps

S38

decimal

0–14

1

Sets the maximum 56K “downstream” speed

at which the modem attempts to connect. The
default maximum speed is 56K bps.

0 = 56K disabled
1 = 56K enabled*
2 = 32000 bps
3 = 34000 bps
4 = 36000 bps
5 = 38000 bps
6 = 40000 bps
7 = 42000 bps
8 = 44000 bps
9 = 46000 bps
10 = 48000 bps
11 = 50000 bps
12 = 52000 bps
13 = 54000 bps
14 = 56000 bps

* with automatic speed selection at maximum
modem speed

S42

decimal

0–1

1

Enables/disables the 56K auto rate. When
56K auto is disabled, fallback to V.34 is also
disabled. 0 = disable; 1 = enable.

S43

decimal

0–1

1

For testing and debugging only. Enables/
disables V.32bis start-up auto mode operation.
0 = disable; 1 = enable.