13

A

SSEMBLING THE

S

TANDS

There are 2 options for assembling the stand. The first option allows the stand to
be self-supporting and moved freely or placed anywhere on the countertop. The
second option is used if the stand will be bolted/hard-mounted to the countertop.

Stand Option 1: Self-supported

For use with kit #46-46128

Step 1

Slide the apron (

MLPN

50-50440)

over the stand (

MLPN

36-00454).

Step 2

Position the stand so it sits under
the tab on the apron. Then secure
the apron to the stand using the
M3 x 6 mm screws
(

MLPN

18-18670) and the #5

washers (

MLPN

18-18671) provided.

Stand Option 2:

Hard-mounted to countertop
For use with kit #46-46351

Step 1

Drill four #39 holes in the countertop.

Step 2

Secure the base (

MLPN

36-36080)

to the countertop with the four
#8 wood screws (

MLPN

18-18057) provided.