MITSUBISHI ELECTRIC V29 User Manual

Page 39

Advertising
background image

MODELS: WD-52627 / 52628 / 62627 / 62628 / 62827 / 62927 / 73727 / 73827 / 73927

Page 39

3. Error Code Operational Check

Note: The TV must be in “Shut Down” and not have been switched Off, to perform the Error Code Opera-

tional Check. When the TV is switched Off, the code automatically resets to “12” No Error.

Pressing the front panel “DEVICE” and “MENU” buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The LED flashes denoting a two digit Error Code, or indicating no problem
has occured since the last Initalization.

Note: The front panel buttons must be used, NOT those on the Remote Control.

The number of flashes indicates the value of the MSD (tens digit) of the Error Code.

The flashing then pauses for approximately 1/2 second.

The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.

The Error Code is repeated a total of 5 times.

Example: If the Error Code is “23”, the LED will flash two times, pause, and then flash three times.

4. Error Codes

The Error Code designations indicating malfunction, or no malfunction, are listed below:

Error Codes

"DEVICE" & "MENU"

Error Codes

Description

12

No error detected

22

Recovery from Reset

32

Lamp cover is Open

34

Lamp abnormality

35

DM Fan failed (Chassis Fan)

36

Exhaust or Lamp Ballast Fan failed

37

DMD Engine Fan failed

38

Lamp temperature abnormally high

39

DMD temperature abnormally high

41

Short is detected (Standby Power Supplies)

42

Lamp Fan failed

44

DVI cable between Format and Engine disconnected

46

DMD Fan failed (JC connector disconnected)

47

DM Temperature too high

48

Engine power supply short detected

51

Speaker Drive circuit short detected

52

HDD excess temperature (V30+ & V31 only)

55

HDD Fan Stopped (V30+ & V31 onlyt)

POWER

LED

STATUS

LED

LAMP

LED

Power
Status

Condition

Off

Yellow

Off

Low

Power

Excess Temperature

Off or On

Off

Yellow

No

change

120w usage time over 7000 Hrs.
150W usage time over 3500 Hrs.

Off

Off

Blinks

Yellow

Low

Power

Lamp Cover open

Off

Blinks

Yellow

Off

"

Filter Cover Open

Off

Off

Red

Stby

Lamp did not turn On

Off

Blinks

Red

Off

Low

Power

Fan Stopped

Off

Red

Off

"

Circuit failure (short or DVI
connector unplugged)

Abnormal LED Indications

Advertising