Electrical information – Maytag MDG31 User Manual

Page 15

Advertising
background image

113430 - 10

Telephone: (641) 787-7000

15

NUMBER OF DRYERS

4

3

2

1

MINIMUM CROSS-

SECTIONAL AREA

SQ IN

120

120

80

54

SQ CM

774.2

774.2

516.1

348.4

MINIMUM ROUND
DUCT DIAMETER

IN

12

12

10

8

CM

30.48

30.48

25.4

20.32

Important

No more than 4 dryers should be connected to 1
main common duct.

The illustration below shows the minimum cross-sectional
area for multiple dryer round or square venting. These figures
must be increased if the main duct run from the last dryer to
where it exhausts to the outdoors is longer than 12 feet (3.66
meters) or has more than 1 elbow in it.

!

NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm)

larger than the duct (all the way around). The duct must be centered
within this opening.

NOTE 2 Distance should be 2 times the diameter of the duct to the nearest

obstruction.

A = MDG31 6-inch (15.24 cm)

MDG51 8-inch (20.32 cm)
MDG77 8-inch (20.32 cm)

B = 12 feet (3.66 meters)

Electrical Information _________________

Electrical Requirements

All electrical connections must be made by a properly licensed
and competent electrician. This is to ensure that the electrical
installation is adequate and conforms to local, state, and
national regulations or codes of the country of origin. In the
absence of such codes, all electrical connections, materials,
and workmanship must conform to the applicable
requirements of the National Electrical Code ANSI/NFPA NO.
70-LATEST EDITION or in Canada, the Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.

Important

Failure to comply with these codes or ordinances,
and/or the requirements stipulated in this manual

can result in personal injury or component failure.

Note

Component failure due to improper installation will
void the warranty.

Each dryer should be connected to an independently protected
branch circuit. The dryer must be connected with copper
wire only. Do not use aluminum wire, which could cause a
fire hazard. The copper conductor wire/cable must be of proper
ampacity and insulation in accordance with electric codes
for making all service connections.

Note

The use of aluminum wire will void the warranty.

An individual ground circuit must be provided to

each dryer, do not daisy chain.
Component failure due to improper voltage application will
void the warranty.
The manufacturer reserves the right to make changes in
specifications at any time without notice or obligation.

Important

A separate protected circuit must be provided to
each dryer.

The dryer must be connected to the electric supply shown
on the data label. In the case of 208 VAC or 240 VAC, the
supply voltage must match the electric service
specifications of the data label exactly.

Important

The wire size must be properly sized to handle the
related current.

Warning

208 VAC and 240 VAC are not the same. Any
damage done to dryer components due to

improper voltage connections will automatically void the
warranty.

!

!

!

!

!

!

NUMBER OF DRYERS

4

3

2

1

MINIMUM CROSS-

SECTIONAL AREA

SQ IN

120

120

80

54

SQ CM

774.2

774.2

516.1

348.4

MINIMUM ROUND
DUCT DIAMETER

IN

12

12

10

8

CM

30.48

30.48

25.4

20.32

Multiple Dryer Venting with 8-Inch (20.32 cm) Diameter

525 cfm (14.87 cmm) Exhaust Connections at Common Duct

MDG51

Multiple Dryer Venting with 8-Inch (20.32 cm) Diameter

560 cfm (15.86 cmm) Exhaust Connections at Common Duct

MDG77

NUMBER OF DRYERS

4

3

2

1

MINIMUM CROSS-

SECTIONAL AREA

SQ IN

80

80

54

30

SQ CM

516.1

516.1

348.4

193.55

MINIMUM ROUND
DUCT DIAMETER

IN

10

10

8

6

CM

25.4

25.4

20.32

15.24

MDG31

Multiple Dryer Venting with 6-Inch (15.24 cm) Diameter

360 cfm (10.19 cmm) Exhaust Connections at Common Duct