Gas specifications for ce approved dryers, Gas specifications for non-ce approved dryers, Mdg31 – Maytag MDG31 User Manual

Page 18: Mdg51, Mdg77

Advertising
background image

18

Maytag Co.

113430 - 10

Gas Specifications for CE Approved Dryers

**

Model

Gas

Type

Nominal

Heating Value

Supply

Pressure

Gross

Heat Input

Fuel

Consumption

Orifice Size

Orifice

(Injector)

Quantity

Burner

Pressure

B tu/ft

3

mb

Btu/hr

kW

DMS

mm

mb

Natural (I

2H

/I

2E

)

1,000

15-30

55,000

16.12

1.557 M

3

/H

22

3.988

1

6.9

Natural (I

2L

)

830

20-35

55,000

16.12

1.876 M

3

/H

22

3.988

1

9.5

Natural (I

2E L L

)

830

15-30

55,000

16.12

1.876 M

3

/H

22

3.988

1

9.5

*

Natural (I

2E+

)

1,000

20

55,000

16.12

1.557 M

3

/H

31

3.048

1

830

25

55,000

16.12

1.876 M

3

/H

31

3.048

1

*

Butane (I

3+

)

3,175

28-30

55,000

16.12

1.162 kg/H

48

1.930

1

*

Propane (I

3+

)

2,500

37

55,000

16.12

1.162 kg/H

48

1.930

1

Butane (I

3B/P

)

3,175

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

18.1

Propane (I

3P

)

2,500

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

24.9

Natural (I

2H

/I

2E

)

1,000

15-30

90,000

26.38

2.549 M

3

/H

29

3.454

2

7.2

Natural (I

2L

)

830

20-35

90,000

26.38

3.071 M

3

/H

29

3.454

2

8.9

Natural (I

2E L L

)

830

15-30

90,000

26.38

3.071 M

3

/H

29

3.454

2

8.9

*

Natural (I

2E+

)

1,000

20

90,000

26.38

2.549 M

3

/H

35

2.794

2

830

25

90,000

26.38

3.071 M

3

/H

35

2.794

2

*

Butane (I

3+

)

3,175

28-30

90,000

26.38

1.901 kg/H

50

1.778

2

*

Propane (I

3+

)

2,500

37

90,000

26.38

1.901 kg/H

50

1.778

2

Butane (I

3B/P

)

3,175

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

18.1

Propane (I

3P

)

2,500

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

24.9

Natural (I

2H

/I

2E

)

1,000

15-30

110,000

32.24

3.115 M

3

/H

22

3.988

2

6.9

Natural (I

2L

)

830

20-35

110,000

32.24

3.753 M

3

/H

22

3.988

2

9.5

Natural (I

2E L L

)

830

15-30

110,000

32.24

3.753 M

3

/H

22

3.988

2

9.5

*

Natural (I

2E+

)

1,000

20

110,000

32.24

3.115 M

3

/H

31

3.048

2

830

25

110,000

32.24

3.753 M

3

/H

31

3.048

2

*

Butane (I

3+

)

3,175

28-30

110,000

32.24

2.324 kg/H

48

1.930

2

*

Propane (I

3+

)

2,500

37

110,000

32.24

2.324 kg/H

48

1.930

2

Butane (I

3B/P

)

3,175

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

18.1

Propane (I

3P

)

2,500

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

24.9

Gas Specifications for Non-CE Approved Dryers

**

Model

Gas

Type

Nominal

Heating Value

Supply

Pressure

Gross

Heat Input

Orifice Size

Orifice

(Injector)
Quantity

Burner

Pressure

B tu /ft

3

in WC

Btu/hr

kW

DMS

mm

in WC

MDG31

Natural

1,000

7.0-13.0

55,000

16.12

20

4.089

1

3.0

*

Liquid Propane

2,500

11.0

55,000

16.12

44

2.184

1

10.0

MDG51

Natural

1,000

7.0-13.0

90,000

26.38

29

3.454

2

3.0

*

Liquid Propane

2,500

11.0

90,000

26.38

47

2.994

2

10.0

MDG77

Natural

1,000

7.0-13.0

110,000

32.24

22

3.988

2

3.0

*

Liquid Propane

2,500

11.0

110,000

32.24

44

2.184

2

10.0

Heat Input/Gas Consumption/Orifice (Injector) Data (For Non-CE [European] Models Only)

Shaded areas are stated in metric equivalents

*

Gas valve’s internal regulator disabled.

** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Shaded areas are stated in metric equivalents

* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)

MDG31

MDG51

MDG77

Advertising