TANDS

Adjustable Stand Hard Mount Installation [Kit #45-45967]

Step 1
Remove the four screws holding the rotating base
[

MLPN

45-45577] to the weighted base

[

MLPN

36-36765].

Step 2
Note the position of the FRONT mark on the
rotating base then use the rotating base as a guide to
drill four pilot holes (Hard Wood - #31 drill or Soft
Wood -#43 drill) in the countertop.

Step 3
Secure the rotating base [

MLPN

45-45577] to the

countertop with the four #10 wood screws
[

MLPN

18-18857] provided.

Step 4
Align the tilt/swivel cup assembly
[

MLPN

45-45967A] with the rotating base

[

MLPN

45-45577] as indicated below.

Step 5
Press down firmly on the tilt/swivel cup assembly
until it snaps into place over the rotating base.

Additional stand options available for purchase:

Wall Mounting Kit [mlpn 45-45968]

Stationary Stand [

MLPN

45-45429]

for use with the adjustable stand