Troubleshooting guide – Metrologic Instruments MS6720 User Manual

Page 29

Advertising
background image

23

T

ROUBLESHOOTING

G

UIDE

The following guide is for reference purposes only. Contact a Metrologic
representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the
limited warranty terms.

All Interfaces

MS6720 Troubleshooting Guide

SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

No LEDS, beep
or motor spin

No power at power up

Check transformer, outlet and
power strip

NOTE:

If it’s a direct connect scanner, the problem could be inadequate power
being supplied to the scanner. It may be necessary to use a Metrologic
transformer for power. Check the fuse in the MCA.

3 beeps on
power up

Non-volatile RAM failure

Contact a Metrologic Rep, if
the unit will not hold the
programmed configuration

Continuous razz
tone on power
up

RAM or ROM failure

Contact a Metrologic Rep, if
the unit will not function

Razz tone and
red LED flash at
power up

VLD failure

Contact a Metrologic Rep

Razz tone and
both LEDs flash
at power up

Scanner motor failure

Contact a Metrologic Rep

Unit scans,
Communicates
and beeps twice

Same symbol timeout set
too short

Adjust same symbol timeout for
a longer time