Metrologic Instruments MS6720 User Manual

Page 33

Advertising
background image

27

T

ROUBLESHOOTING

G

UIDE

(C

ONTINUED

)

RS-232 only

SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

Power-up OK

Scans OK

Does not
communicate
properly to the host

Com port at the host not
working or not configured
properly

Cable not connected to
the proper com port

Com port not operating
properly

Check to make sure the baud
rate and parity of the scanner
and the communication port
match and the program is
looking for “RS-232" data.

NOTE:

Metrologic’s default of 7 data bits, space parity is usually what is expected
when an IBM compatible type PC is configured for 8 data bits, no parity.

SYMPTOMS

SOLUTION

Host receiving data but data does
not look correct

Check that the scanner and host are
configured for the same interface format

Characters are being dropped

Add some intercharacter delay to the
transmitted output. This can be
programmed into the scanner through
ScanSelect

RS-232 Demonstration Program

If an RS-232 scanner is not communicating with your IBM compatible PC, key in
the following BASIC program to test that the communication port and scanner are
working. This program is for demonstration purposes only. It is only intended to
prove that cabling is correct, the com port is working, and the scanner is working.
If the bar code data displays on the screen while using this program, it only
demonstrates that the hardware interface and scanner are working. At this point,
investigate whether the application software and the scanner configuration match.
If the application does not support RS-232 scanners, a software wedge program
that will take RS-232 data and place it into a keyboard buffer may be needed.
This program tells the PC to ignore RTS-CTS, Data Set Ready (DSR) and Data
Carrier Detect (DCD) signals. If the demonstration program works and yours still
does not, jumper RTS to CTS and Data Terminal Reading (DTR) to DCD and
DSR on the back of your PC.

10

CLS

20

ON ERROR GOTO 100

30

OPEN “COM1:9600,S,7,1,CS0,DS0,CD0,LF” AS #1

35

PRINT “SCAN A FEW BAR CODES”

40

LINE INPUT #1, BARCODE$

50

PRINT BARCODE$

60

K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766

70

GOTO 40

100

PRINT “ERROR NO.”; ERR; “ PRESS ANY KEY TO TERMINATE.”

110

K$ = INKEY$: IF K$ = “” THAN GOTO 110

32766

CLOSE: SYSTEM

32767

END

Advertising