Cleaning the inlet hose filter

The washer has two water inlet filters to
protect each inlet valve. Check and
clean these filters every 6 months. This
may have to be done more frequently
with some water supplies.

Cleaning the inlet hose filters

^ Turn off the water faucet.

^ Unscrew the inlet hose from the valve

by turning the connector
counterclockwise using a wrench if
necessary.

^ Remove the rubber seal,

1

, from the

connector.

^ Using needle nose pliers, grasp the

plastic filter,

2

, and pull it out of the

hose connector.

^ Clean the filter under running water

and carefully remove any large
particles.

^ Replace the filter and seal and

reconnect the hose.

Slowly turn on the faucet and check
for leaks. If water leaks, tighten the
hose connection.

Cleaning the filter in the inlet valve

^ Using pliers carefully loosen and

remove the plastic hose connector
from the inlet valve.

^ Using needle nose pliers, remove the

plastic filter by pulling on the bar (see
illustration). Rinse under running
water and return. Replace the filter
and seal then reconnect the hose.

Both filters

must

be put back in

place after cleaning.