Miller Electric Axcess 450 User Manual

Page 33

Advertising
background image

OM-220 389 Page 27

C. Best Setup

Ref. 804 462-A

1

Welding Power Source

2

Electrode Cable

3

Feeder Cable

4

Work Cable

5

Voltage Sensing Lead

6

Wire Feeder

7

Workpiece

This arrangement is the best setup for
proper voltage sensing at the workpiece.
Voltage feedback to the welding power
sources will more accurate and result in
reliable arc starts and better arc quality.

Current Flow Path

1

2

3

6

3

2

1

6

4

7

5

5

4

Advertising