Process control module pc4 diagnostic led’s, Diagnostic led’s on process control module pc4, 2. process control module pc4 diagnostic led’s – Miller Electric Axcess 450 User Manual

Page 39: 3. diagnostic led’s on process control module pc4

Advertising
background image

OM-220 389 Page 33

1

Process Control Module PC4

Diagnostic LED’s are visible inside unit,
located on PC4 mounted on the top tray.

Refer to Section 9-3 for information on
diagnostic LED’s.

Reinstall cover after checking diagnostic
LED’s.

216 956-A / Ref. 803 419-B

9-2.

Process Control Module PC4 Diagnostic LED’s

1

LED2

LED1

LED4

LED3

9-3.

Diagnostic LED’s On Process Control Module PC4

LED

Status

Diagnosis

1

On

Indicates −25 volts dc is present on process control module PC4

Off

Indicates −25 volts dc is not present on process control module PC4

2

On

Indicates +25 volts dc is present on process control module PC4

Off

Indicates +25 volts dc is not present on process control module PC4

3,4

On

See Network Status Table in Section 9-4

Off

See Network Status Table in Section 9-4