Location Requirements

You will need

A location that allows proper exhaust installation. See “Venting
Requirements.”

A separate 30-amp circuit.

If using a power supply cord, a grounded electrical outlet

within 2 ft (610 mm) of either side of dryer. See “Electrical
Requirements.”

A sturdy floor to support total dryer weight of 200 lbs. (90.7 kg).
Also consider combined weight of a companion appliance.

A level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer
Feet Kit, Part Number 279810. Clothes may not tumble properly
and automatic sensor cycles may not operate correctly if dryer is
not level.

For a garage installation, place dryer at least 18" (457 mm)
above floor. If using a pedestal, you will need 18" (457 mm) to
bottom of dryer.

Steam models only: Cold water faucets located within

4 ft. (1.2 m) of dryer, and water pressure of 20-100 psi

(137.9-689.6 kPa). Cold water supply may come from

washer using “Y” connector provided.

Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer may not shut off at the end of an
automatic sensor cycle, possibly resulting in longer drying times.

Do not install or store dryer where it will be exposed to water and/or
weather.

Check code requirements. Some codes limit, or do not permit,
installation of dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.

Installation clearances

Location must be large enough to allow dryer door to open fully.

Dryer Dimensions

29"

(737 mm)

22

1

/

4

"

(565 mm)

29

1

/

4

"

(743 mm)

43

1

/

2

"

(1105 mm)

NOTE: Most installations require minimum 5" (127 mm) clearance
for exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer.
Dryer has been tested for spacing of 0" (0 mm) clearance on sides
and rear. Consider recommended spacing for following reasons:

Consider additional spacing for ease of installation and service.

May need additional clearance for wall, door, and floor moldings.

Consider additional spacing on all sides of dryer to reduce noise
transfer.

For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Equivalent
ventilation openings in louvered doors are acceptable.

Consider spacing for companion appliance.

Additional space required for rear exhaust of dryer to right or left.

14" máx.*

(356 mm)

29"

(737 mm)

5"

(127 mm)

1"

(25 mm)

1"

(25 mm)

18"*

(457 mm)

3"*

(76 mm)

3"*

(76 mm)

29

1

/

4

"

(743 mm)

48"

2

*

(310 cm

2

)

24"

2

*

(155 cm

2

)

Recessed

area

Side view- closet

or confined area

Closet door with

vents

*Required spacing

Mobile home - Additional installation requirements

Dryer is suitable for mobile home installations. Installation must
conform to Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280) or Standard CAN/
CSA-Z240 MH.

Mobile home installations require:

Metal exhaust system hardware, available for purchase from
your dealer.

Special provisions must be made in mobile homes to introduce
outside air into dryer. Openings (such as a nearby window)
should be at least twice as large as dryer exhaust opening.