Tighten strain relief screw, Wire connection: power supply cord, A. 3-wire receptacle (nema type 10-30r) – Maytag W10267633A User Manual

Page 8: B. 3-wire plug, C. neutral prong, D. spade terminals with up turned ends, E.3/4" (19 mm) ul listed strain relief, F. ring terminals, G. neutral (white or center wire), A. external ground conductor screw

Advertising
background image

8

4. Place the hooked ends of the other direct wire cable wires under

the outer terminal block screws (hooks facing right). Squeeze
hooked ends together. Tighten screws.

5. Tighten strain relief screw.

6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to

“Venting Requirements.”

3-wire connection: Power supply cord

Use where local codes permit connecting cabinet-ground
conductor to neutral wire.

A

B

D

C

E

F

G

A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug

C. Neutral prong
D. Spade terminals with up turned ends

E.3/4" (19 mm) UL listed strain relief

F. Ring terminals

G. Neutral (white or center wire)

1. Loosen or remove center, silver-colored terminal block screw.

2. Connect neutral wire (white or center wire) of power supply cord

to the center, silver-colored terminal screw of the terminal block.
Tighten screw.

A

B

C

D

E

A. External ground conductor screw
B. Neutral ground wire

C. Center, silver-colored terminal block screw
D. Neutral wire (white or center wire)

E. 3/4" (19 mm) UL listed strain relief

3. Connect the other wires to outer terminal block screws. Tighten

screws.

4. Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. You have completed your electrical connection. Now go to

“Venting Requirements.”

3-wire connection: Direct wire

Use where local codes permit connecting cabinet-ground
conductor to neutral wire.

Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer can

be moved if needed.

Strip 3

1

/

2

" (89 mm) of outer covering from end of cable. Strip

insulation back 1" (25 mm). If using 3-wire cable with ground wire,
cut bare wire even with outer covering. Shape ends of wires into a
hook shape.

1"

(25 mm)

3½"

(89 mm)

When connecting to the terminal block, place the hooked

end of the wire under the screw of the terminal block (hook facing
right), squeeze hooked end together and tighten screw, as shown.

1. Loosen or remove center, silver-colored terminal block screw.