Marantz PD4293D User Manual

Page 50

Advertising
background image

43

15. GREEN Gain Data

Function
The external control equipment changes the GREEN Gain Data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

04H

DATA00 to DATA03

CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: GREEN Gain Flag

02H

DATA02: GREEN Gain 1 (Bias)

D8H: -40

FFH: -1
00H: 0

IEH: +30

DATA03: GREEN Gain2 (Drive)

D8H: -40

FFH: -1
00H: 0

IEH: +30

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: GREEN Gain Flag

02H

16. BLUE Gain Data

Function
The external control equipment changes the BLUE Gain Data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

04H

DATA00 to DATA03

CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BLUE Gain Flag

03H

DATA02: BLUE Gain1(Bias)

D8H:-40

FFH:-1
00H: 0

IEH: +30

DATA03: BLUE Gain2(Drive)

D8H: -40

FFH:-1
00H: 0

IEH:+30

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BLUE Gain Flag

03H

17. NR MODE Set

Function
The external control equipment sets the NR (Noise Reduction) mode of the
plasma monitor.
Transmission Data

DFH

80H

60H

C0H

01H

DATA00 CKS

DATA00: 01H: NR OFF

02H: NR-1
03H: NR-2
04H: NR-3

ACK

7FH

60H

80H

C0H

01H

DATA00 CKS

DATA00: 01H: NR OFF

02H: NR-1
03H: NR-2
04H: NR-3

18. BASS Gain Data

Function
The external control equipment changes the BASS gain data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: BASS Gain Flag

03H

DATA02: BASS Gain

F3H: -13

FFH: -01
00H: 0
01H: +01

0DH: +13

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: BASS Gain Flag

03H

19. TREBLE Gain Data

Function
The external control equipment changes the TREBLE gain data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: TREBLE Gain Flag

04H

DATA02: TREBLE Gain

F3H: -13

FFH: -01
00H: 0
01H: +01

0DH: +13

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: TREBLE Gain Flag

04H

Advertising