Marantz PD4293D User Manual

Page 51

Advertising
background image

44

20. BALANCE Gain Data

Function
The external control equipment changes the BALANCE gain data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: BALANCE Gain Flag

02H

DATA02: BALANCE Gain

EAH: -22

FFH: -01
00H: 0
01H: +01

16H: +22

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: BALANCE Gain Flag

02H

21. SCREEN MODE Select

Function
The external control equipment switches the screen mode of the plasma monitor.

Transmission Data

DFH

80H

60H

51H

01H

DATA00 CKS

DATA00: 02H: STADIUM

03H: ZOOM
04H: NORMAL
05H: FULL

ACK

7FH

60H

80H

51H

01H

DATA00 CKS

DATA00: 02H: STADIUM

03H: ZOOM
04H: NORMAL
05H: FULL

22. V. POSITION Gain Data

Function
The external control equipment changes the V. POSITION gain data of the
plasma monitor.
Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V. POSITION Gain Flag

01H

DATA02: V. POSITION Gain

C0H: -64

FFH: -01
00H: 0
01H: +01

40H: +64

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V. POSITION Gain Flag

01H

23. H. POSITION Gain Data

Function
The external control equipment changes the H. POSITION gain data of the
plasma monitor.
Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H. POSITION Gain Flag

02H

DATA02: H. POSITION Gain

80H: -128

FFH: -01
00H: 0
01H: +01

7FH: +127

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H. POSITION Gain Flag

02H

24. V-HEIGHT Gain Data

Function
The external control equipment changes the V-HEIGHT gain data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V-HEIGHT Gain Flag

07H

DATA02: V-HEIGHT Gain

00H: 0

40H: +64

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V-HEIGHT Gain Flag

07H

25. H-WIDTH Gain Data

Function
The external control equipment changes the H-WIDTH gain data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H-WIDTH Gain Flag

08H

DATA02: H-WIDTH Gain

00H: 0

40H: +64

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H-WIDTH Gain Flag

08H

Advertising