Keyboard wedge only – Metrologic Instruments MS7120 User Manual

Page 29

Advertising
background image

25

T

ROUBLESHOOTING

G

UIDE

(C

ONTINUED

)

Keyboard Wedge Only

SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

The unit scans
the bar code
but there is no
data

Configuration is not
correct

Make sure the scanner is
configured for the appropriate
mode. Check internal jumper

The unit scans
but the data is
not correct

Configuration is not
correct

Make sure that the proper PC
type AT, PS2 or XT is selected.
Verify correct country code and
data formatting are selected.
Adjust intercharacter delay
SYMPTOM

The unit is
transmitting
each character

Configuration is not
correct

Increase the interscan code
delay setting. Adjust whether the
F0 break is transmitted. It may
be necessary to try this in both
settings.

Alpha
characters
show as lower
case

Computer is in Caps
Lock mode

Enable Caps Lock detect setting
of the scanner to detect whether
the PC is operating in Caps Lock

Everything
works except
for a couple of
characters

These characters may
not be supported by
that country’s key look
up table

Try operating the scanner in Alt
mode