36

1

10

S

CANNER AND

C

ABLE

T

ERMINATIONS

Scanner Pinout Connections

The MS7120 scanner interfaces terminate
to a 10-pin modular jack. The serial # label
indicates the interface enabled when the
scanner is shipped from the factory. Some
units have internal jumpers that can be moved
to enable a different electrical interface.
Current combinations are listed below.

MS7120-9 OCIA

JP1 = Open and JP2 = Closed

MS7120-67 RS-232/LTPN

JP1 = Closed and JP2 = Open

Pin

Function

Function

1

Ground

Ground

2

RS-232 Transmit Output

RS-232 Transmit Output

3

RS-232 Receive Input

RS-232 Receive Input

4

RDATA

RTS Output

5

RDATA Return

CTS Input

6

Clock in

DTR Input/LTPN Source

7

Clock out

Reserved

8

Clock in Return/Clock out
Rtrn

LTPN Data

9

+5VDC

+5VDC

10

Shield Ground

Shield Ground

MS7120-47 Keyboard Wedge

JP1 = Open and JP2 = Closed

MS7120-41 RS-232/LTPN

JP1 = Closed and JP2 = Open

Pin

Function

Function

1

Ground

Ground

2

RS-232 Transmit Output

RS-232 Transmit Output

3

RS-232 Receive Input

RS-232 Receive Input

4

PC Data

RTS Output

5

PC Clock

CTS Input

6

KB Clock

DTR Input/LTPN Source

7

PC +5V

Reserved

8

KB Data

LTPN Data

9

+5VDC

+5VDC

10

Shield Ground

Shield Ground