SECTION 11 − STANDARD PULSE WELDING PROGRAMS

FOR XMT 304 INVERTER WELDING POWER SOURCES

Apk = Peak Amperage, Vpk = Peak Voltage, Abk = Background Amperage, PPS = Pulses Per

Second, PWms = Pulse Width (milliseconds). The following eight pulse welding programs are in

the memory of the wire feeder. Use this information if it is necessary to change a standard

program, or as a basis to build your own custom program. If at any time while changing a

standard program, or while building your own custom program, you want to go back to the

standard program in the wire feeder, perform a system reset according to Section 9-2.

Note

11-1. Program 1 − Steel

Wire Size/Type: .030”

Gas: Ar - CO

2

or Ar - Oxy / 40 CFH (19 L/m)

IPM / MPM

Apk

Vpk

Abk

PPS

PWms

COMMENTS

700 / 17.8

400

37.2

127

137

1.8

400 / 10.2

340

33.3

94

98

1.6

200 / 5.1

305

29.6

58

63

1.4

100 / 2.5

285

27.7

32

36

1.4

11-2. Program 2 − Steel

Wire Size/Type: .035”

Gas: Ar - CO

2

or Ar - Oxy / 40 CFH (19 L/m)

IPM / MPM

Apk

Vpk

Abk

PPS

PWms

COMMENTS

700 / 17.8

400

34.9

170

188

2.2

400 / 10.2

400

32.5

95

113

1.9

200 / 5.1

370

29.9

53

70

1.7

100 / 2.5

350

29.7

26

40

1.7

11-3. Program 3 − Steel

Wire Size/Type: .045”

Gas: Ar - CO

2

or Ar - Oxy / 40 CFH (19 L/m)

IPM / MPM

Apk

Vpk

Abk

PPS

PWms

COMMENTS

500 / 12.7

400

32.0

200

200

3.5

400 / 10.2

400

31.0

165

165

3.0

200 / 5.1

375

29.0

97

97

2.5

100 / 2.5

366

27.4

54

50

2.1

Advertising