14-3. Error Displays

Ref. ST-155 222

1

Release Trigger Error Display

This appears if the trigger is closed

when the unit power is turned on, or

if the trigger is stuck or defective.
2

No Volt Sensed Error Display

The arc voltage sense circuit is not

receiving feedback. Check voltage

sensing connections. Check

connections at 14-position plugs/

receptacles at the unit and welding

power source.
Turn unit off and back on after

correcting problem.
If this error continues to occur when

pulse welding, it may help to select

Hot Start.
3

Memory CRC Error Display

The data in the program indicated is

not the same data that was saved.
Perform a system reset.
4

Memory Range Error Display

The data in the program indicated is

out of usable range.
Go through pulse parameters to

make sure they do not exceed

settings of the Range display or per-

form a system reset.
5

No Tach Sensed Error Display

The motor tach feedback is not

reaching the control. Check

connections.
Press front panel Parameter Select

to clear error.
6

Arc Start Error Display

This appears when pulse welding

and current is detected but the arc

cannot be started. Check and

correct program pulse parameters

and voltage settings. Check voltage

sensing connections.

Press front panel Parameter Select

to clear error.
7

Arc Stop Error Display

This appears when pulse welding

and the motor does not stop at the

end of the weld. If there is high

frequency being used in the area,

turn it off. A motor brake circuit prob-

lem can also cause this error.
Press front panel Parameter Select

to clear error.
8

Minimum Gas Flow Error

This appears when gas flow falls

below the minimum CFH set (xx in

example). Adjust gas flow to bring it

above set value.
Press front panel Parameter Select

to clear error.
9

Maximum Gas Flow Error

This appears when gas flow is

above the maximum CFH set (xx in

example). Adjust gas flow to bring it

below set value.
Press front panel Parameter Select

to clear error.
10 Gas Out Of Range Error
This appears when gas flow is

greater than 100 CFH. To protect

the internal sensor, the unit shuts

down until the gas flow can be

adjusted below 100 CFH.
11 Coolant Flow Error
This appears only when coolant

flow switch option is installed.

Check coolant recirculating

system.
12 Unlocked Program Error

Display

This appears when attempting to

run an unlocked program while

other programs are locked. Either

lock the unlocked program or select

a different program that is locked.

R e l e a s e

T r i g g e r

1

N o

V o l t

S e n s e d

E r r o r

M e m o r y

C R C

P r g

1

E r r o r

3

4

M e m o r y

R a n g e

P r g

1

E r r o r

2

N o

T a c h

S e n s e d

E r r o r

A r c

S t a r t

E r r o r

A r c

S t o p

E r r o r

5

6

7

M i n C F H x x

Ga s F l o w

E r r o r

Ma x C F H x x

G a s F l o w

E r r o r

G a s

O u t

o f R a n g e

E r r o r

C o o l a n t

F l o w

E r r o r

11

8

9

10

U n l o c k e d

P r o g r a m

E r r o r

12