Specifications

Rated Cutting

Maximum Open-

Type of Output

Plasma Gas

Rated Output

Rated Cutting

Capacity

Maximum Open-

Circuit Voltage DC

Direct Current, Straight

50 A @ 110 Volts DC,

0.7 in (16 mm)

Direct Current, Straight

Polarity (DCEN)

Air Or Nitrogen Only

50 A @ 110 Volts DC,

50% Duty Cycle

0.7 in (16 mm)

At 10 IPM

350

2-2.

Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-
utes that unit can cut at rated load
without overheating.

If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before cutting.

Y

Exceeding duty cycle can
damage unit and void war-
ranty.

50% Duty Cycle

Overheating

0

15

A

OR

Reduce Duty Cycle

Minutes

duty1 4/95

5 Minutes Cutting

5 Minutes Resting

2-3.

Cutting Speed

The cutting speed curve shows the
recommended maximum cutting
speed capabilities of the power
source and torch for mild steel of
various thickness.

Y

Exceeding recommended
cutting speeds will cause
rapid erosion of the tip and
electrode.

ST-191 605

Cutting speed is approximately
10 inches per minute at 0.7 in (18
mm) mild steel thickness at max
setting/tip saver mode.

The following curve represents the best cutting scenario achieved using
Extended Cutting consumables, no extension cord and a Miller Bobcat
welding generator with a Kohler engine. Some reduction in performance will
occur with the use of extension cords (approximately 5% per 25 feet of
extension cord), and using shield cutting consumables (approximately 10%).