Multi-Tech Systems MT5600ZDX User Manual
Page 46

46
Model MT5600ZDX
S16
General Bit Mapped Test Options Status. Indicates the Test in
progress status: Default 0.
Bit 0
Local Analog Loopback
0 = Disabled (Default)
1 = Enabled (&T1)
Bit 1
Not Used
Bit 2
Local Digital Loopback
0 = Disabled (Default)
1 = Enabled (&T3)
Bit 3
Remote Digital Loopback (RDL) status
0 = Modem not in RDL (Default)
1 = RDL in progress
Bit 4
RDL Requested (AT&T6)
0 = RDL not requested (Default)
1 =RDL requested (&T6)
Bit 5
RDL with self test
0 = Disabled (Default)
1 =Enabled (&T7)
Bit 7
Not used
S18
decimal 0255
0
Sets the length of time, in sec-
onds, that the modem conducts a
test (commanded by &Tn) before
returning to the command mode.
If this register value is zero, the
test will not automatically termi-
nate; the test must be terminated
from the command mode by issu-
ing and &T0 or H command.
When S18 is non-zero, the mo-
dem returns the OK message upon
test termination.