SECTION 7 − OPERATING AUXILIARY EQUIPMENT

7-1. 110 Volt Receptacles

Ref. 217 358-B

1

110/55V 32 A AC Receptalce RC11

2

110/55V 16A AC Receptacle RC12

Receptacles RC11 and RC12 supply 60 Hz

single-phase power at weld/power speed.
Maximum output from RC11 is 3.5 kVA/kW.

Maximum output from RC12 is 1.8 kVa/kW.
Maximum combined output of RC11 and

RC 12 is 4.4 kVa/kW.
3

Circuit Breaker CB6

4

Circuit Breaker CB5

CB6 protects RC12 from overload. If a cir-

cuit breaker opens, the receptacle does not

work. Press button to reset breaker.

Circuit breaker CB5 protects receptacle

RC11 and the generator winding from over-

load. If CB5 opens, the receptacles do not

work. Place CB5 switch in On position to

reset circuit breaker.

.

If a circuit breaker continues to open,
contact Factory Authorized Service

Agent.

.

Generator power decreases as weld

output increases.