Technical data 39, Technical data – Miele DA 217-2 User Manual

Page 39

Advertising
background image

Technical data

Rated load
DA 216-2, 217-2, 219-2 . . . . . . . 222 W

Lighting . . . . . . . . . . . . . . . . . 2 x 11 W

Voltage
UK, IRL, NZ . . . . . . . . . . . . . . . . . 230 V
AUS . . . . . . . . . . . . . . . . . . . . . . . 240 V

Frequency . . . . . . . . . . . . . . . . ~ 50 Hz

Fuse rating (UK) . . . . . . . . . . . . . . . 13 A

Fuse rating (IRL) . . . . . . . . . . . . . . 10 A

AUS, NZ:

Plug rating . . . . . . . . . . . . . . . . . . . 10 A

Test marks . . . . . . . . . . Electrical safety

. . . . . . . . . . . . . . . . . . . . . . C-Tick Mark

Electrically suppressed
according to AS/NZS 1044

Fan performance

Extraction power according to
EN 61591

Extraction system ø 150 mm:
Level I . . . . . . . . . . . . . . . . . . . 220 m

3

/h

Level II . . . . . . . . . . . . . . . . . . . 335 m

3

/h

Level III . . . . . . . . . . . . . . . . . . 440 m

3

/h

Intensive level . . . . . . . . . . . . . 640 m

3

/h

Extraction system ø 125 mm:
Level I . . . . . . . . . . . . . . . . . . . 210 m

3

/h

Level II . . . . . . . . . . . . . . . . . . . 305 m

3

/h

Level III . . . . . . . . . . . . . . . . . . 405 m

3

/h

Intensive level . . . . . . . . . . . . . 590 m

3

/h

unrestricted . . . . . . . . . . . . . . . 690 m

3

/h

Recirculation with charcoal filter:

Level I . . . . . . . . . . . . . . . . . . . 180 m

3

/h

Level II . . . . . . . . . . . . . . . . . . . 290 m

3

/h

Level III . . . . . . . . . . . . . . . . . . 390 m

3

/h

Intensive level . . . . . . . . . . . . . 485 m

3

/h

Active charcoal filter:
Miele active charcoal filter DKF 6

For EXT models the rated load and ex-
traction power will depend on the type
of external fan fitted.