Connection to evacuation duct

The vent hose must use the shortest and

straightest route possible from the tumble

dryer to the evacuation duct. Trim or cut the

vent hose if it is too long. If necessary, the

vent hose can be extended to a maximum

of 8 metres (inner diameter 102 mm). If a

longer hose is needed, a larger inner diam-

eter is required in order to maintain the

tumble dryer’s fan capacity.

Any bends must be as gradual as possible.

If 90º bends are necessary, there must be

no more than four. Multiple bends reduce

the tumble dryer’s fan capacity.

Caution!

Air from the tumble dryer must not be fed

through ducts used for equipment that

burns gas or other fuels.

Examples of

installations

a

b

c

Installation in a hot environment

When installing in small rooms with high at-

mospheric humidity where there is a risk of

the temperature exceeding 25 °C, there is a

risk of condensation water accumulating in

a kink and obstructing the air flow, resulting

in poor drying.

In such situations the hose must be fitted

horizontally (b) or downwards (c) from the

tumble dryer.