Multi-Tech Systems MTCBA-C-U User Manual

Page 31

Advertising
background image

Chapter 4 – Troubleshooting and Frequently Asked Questions

Multi-Tech Systems, Inc. MultiModem CDMA USB Wireless Modem User Guide

31

When I try to make a data call using ‘ATD<number>’, I get a NO CARRIER response.

•

Check ‘AT+CEER’ for NO CARRIER reason and look it up in Reference Guide.

•

Check the number that you are dialing.

•

Make sure you have CSD service.

•

Check registration and signal to make sure modem is registered and getting good signal: +CREG, +CSQ.

•

Make sure you went through the activation procedures correctly.

How do I make a CSD dial-up connection in Windows to my ISP?

•

Create a dial-up connection to the ISP’s access # and use the correct password and username.

•

You must have CSD service.

Does this modem support High-Speed Circuit-Switched Data (HSCSD)?

•

No, our CDMA modems do not support HSCSD.

The modem will not answer.

•

Set the modem to autoanswer with ‘ATS0=1’ and ‘AT&W’ to store the setting.

•

Send ‘ATA’ to the modem once the RING is indicated on the terminal screen.

•

You may need to set the modem to ignore DTR, ‘AT&D0’, if your system doesn’t provide DTR.

The modem answers, but does nothing.

•

Modem is answering in voice mode.

•

Voice: Need a voice cable; such as our “Y” cable.

•

Data: Make sure you set ‘AT+CICB=0’ to make the modem answer in data mode.

How does faxing work?

•

The CDMA modems only support Class 2.0 Group 3 faxing.

•

Need fax services setup on the account.

•

Need fax software that supports the modem; e.g., WinFax Pro v10.0.

•

Need to set ‘AT+CICB=1’ for modem to answer in fax mode.

When I set the S0 command, store it with &W; then send “ATZ” to the modem, the command goes back to
the default of 0?

•

This is a bug in the modem. S0 will store just fine, as long as “ATZ” doesn’t get sent to the modem.

After I set the E and &D commands followed by &W, it looks to be stored okay, but as soon as I recycle
power on the unit the E and &D commands get set back to default of E1 and &D2.

•

This is a bug in the modem. These commands will not store correctly. If modems are powered back up and
an “ATZ” is sent to the modem, then &D and E will load to your stored settings correctly.

•

Firmware versions 210 and above fixes the storage or the E command.

After I set the Q, V, and &S commands followed by &W, if I recycle power or send ATZ to the modem the
settings will get set back to default.

•

Bug in the modem. These commands will not store.

What is the max supported serial baud rate?

•

230,400 bps is the max.



Advertising