Ice Machine Operation

Section 3

3-12

Part Number 000002688

Water Level Probe Removal

QF400/QC700/QF800/QF2300

Water Level Probe Removal

1. Place the toggle switch in the OFF position, turn off the

water supply and disconnect electrical power to the ice
machine.

2. Disconnect water supply line at float valve quick disconnect

by depressing stainless steel lever.

3. Pull up on water level probes to remove.

4. Disconnect wires from water level probes or control board.

QF400

QC700/QF800

QF2300

Water Reservoir Cover Removal

1. Place the toggle switch in the OFF position, turn off

the water supply and disconnect electrical power to
the ice machine.

2. Remove water level probes.

3. Remove water float valve coil.

4. Depress coil and rotate 1/4 turn counterclockwise.

5. With coil wires attached, lift coil off enclosure tube.

6. QF0800/QC0700 ONLY Rotate quarter turn

fasteners counterclockwise.

7. QF0800/QC0700 ONLY Remove cotter key and pin

from ice chute.

8. Remove top cover from float reservoir.

QC700/QF800 Shown

WATER LEVEL

PROBES

SV2043

WATER LEVEL

PROBES

SV2028

WATER LEVEL

PROBES

SV1791

3

4

5

6

SV2030