Section 3

Ice Machine Operation

Part Number 000002688

3-13

Water Reservoir Cover Removal

QF2300

1. Place the toggle switch in the OFF position, turn off

the water supply and disconnect electrical power to
the ice machine.

2. Remove water level probes.

3. Remove water float valve coil.

4. Depress coil and rotate 1/4 turn counterclockwise.

5. With coil wires attached, lift coil off enclosure tube.

6. Remove top cover from float reservoir.

QF2300 Shown

Float Valve Removal

1. Place the toggle switch in the OFF position, turn off

the water supply and disconnect electrical power to
the ice machine.

2. Disconnect water supply line at float valve quick

disconnect by depressing stainless steel lever.

3. Remove water float valve coil.

4. Depress coil and rotate 1/4 turn counterclockwise.

5. With coil wires attached, lift coil off enclosure tube.

6. QF0800/QC0700/QF2300 ONLY Rotate quarter turn

fasteners counterclockwise.

7. QF0800/QC0700 ONLY Remove cotter key and pin

from ice chute.

8. Remove top cover from float reservoir.

9. Lift float valve out of float reservoir.

QC700/QF800 Shown

2

3, 4, 5

6

SV1791

FLOAT VALVE

SV2015