Plumbing, Drainage – Miele G 7883 User Manual

Page 57

Advertising
background image

Drainage

^ The drainage system is fitted with a

non-return valve which prevents dirty
water from flowing back into the
machine via the drain hose.

^ The machine should preferably be

connected to a

separate

drainage

system onsite.
If separate drainage is not available
contact your Miele application
specialist for advice.
The onsite drain connection point
should be located between 1 ft.
(0.3 m) and 3 ft. (1 m)

above the

lower edge of the machine

.

If it is lower than 1 ft. (0.3 m), lay the
hose in a curve at a height of at least
1 ft. (0.3 m).
The drainage system must be able to
take a minimum drainage flow of
16 l/min.

^ The drain hose is approx. 5 ft. (1.5 m)

long, is flexible and has an internal
diameter of

7

/

8

in. (22 mm). It must

not be shortened. Hose clamps are
supplied for securing it in position.

^ A longer drain hose (up to 12 ft. [4 m]

long) is available to order from the
Miele Technical Service Department.

^ The drainage system must not

exceed 12 ft. (4 meters).

^ See the supplied installation diagram.