Electrical connection 58, Electrical connection, Warning this appliance must be grounded – Miele G 7883 User Manual

Page 58

Advertising
background image

,

All electrical work must be

performed by a qualified person in
accordance with local and national
safety regulations.

The machine comes equipped for
connection to a 208 V, 60 Hz, 3 phase
power supply. It is equipped with a 6 ft.
long, 12/4 AWG power cord, without a
plug. A plug, rated for the required
power which will fit the receptacle, is to
be supplied by the electrician doing the
installation. It should be connected to
the main power supply.

Voltage:

208 V, 3 phase

Frequency:

60 Hz

Rated Load:

6 kW

Circuit breaker:

3 x 20 A

Black : connect to L1 (hot)

Red:

connect to L2 (hot)

White: connect to L3 (hot)

Green: connect to GND (ground)

It can be converted to use a single
phase power supply in accordance
with the conversion and wiring diagram.
The cord must be changed from a
12/4 AWG to a 10/3 AWG. Contact
Miele Technical Service for more
information

Voltage:

208 V, 1 phase

Frequency:

60 Hz

Rated Load:

6 kW

Circuit breaker:

2 x 30 A

^ Connection should be made via a

suitable isolator, with an "On/Off"
button easily accessible for servicing
work.

^ A damaged power cord must only be

replaced with a genuine Miele cord
by a Miele service technician.

WARNING
THIS APPLIANCE MUST BE
GROUNDED

Electrical connection

58