4. fuel consumption, 5. duty cycle and overheating – Miller Electric Big Blue 300 P User Manual

Page 18

Advertising
background image

OM-4433 Page 14

4-4. Fuel Consumption

The curve shows typical fuel use

under weld or power loads.

217 509

IDLE

DC WELD AMPERES AT 100% DUTY CYCLE

U.S. GAL/HR.

0.00

0.25

0.50

0.75

1.00

1.25

1.50

1.75

2.00

0

50

100

150

200 250

300

350

400

Continuous Welding

4-5. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-

utes that unit can weld at rated load

without overheating.
Y Exceeding duty cycle can

damage unit and void

warranty.

100% Duty Cycle At 250 Amperes

217 515

10

15

20

25 30

40 50 60

80

100

CC

CV

1000

800
600
500
400

300
250
200

150

100

WELD

AMPERES

% DUTY CYCLE

Advertising