10. checking generator brushes – Miller Electric Big Blue 300 P User Manual

Page 42

Advertising
background image

OM-4433 Page 38

8-10. Checking Generator Brushes

Ref 2114 778−D / S−0233−A

Y Stop engine and let cool.
1

Generator Brush With Spring

Mark and disconnect leads at brush hold-

er cap. Remove brushes.
Replace brushes if damaged or if brush

material is at or near minimum length.

1

5/16 in. (8 mm)

Minimum Length

9/16 in. (14.3 mm)

New Length

Replace

Damaged Brushes

Notes

16 Gauge (.063 in)

22 Gauge (.031 in)

24 Gauge (.025 in)

20 Gauge (.037 in)
18 Gauge (.050 in)

14 Gauge (.078 in)

1/8 in (.125 in)

3/16 in (.188 in)

1/4 in (.25 in)

5/16 in (.313 in)

3/8 in (.375 in)

1/2 in (.5 in)

MATERIAL THICKNESS REFERENCE CHART

Advertising