OM-4433 Page 15

4-6. AC Generator Power Curve

217 519

The ac power curve shows the gen-

erator power in amperes available

at the 120 and 240 volt receptacles.

0

40

80

120

160

0

20

40

60

80

AC AMPERES IN 120 V MODE

AC AMPERES IN 240 V MODE

300

250
200

150

100

50

0

150

125

100

75

50

25

0

AC VOL

TS

Notes

16 Gauge (.063 in)

22 Gauge (.031 in)

24 Gauge (.025 in)

20 Gauge (.037 in)
18 Gauge (.050 in)

14 Gauge (.078 in)

1/8 in (.125 in)

3/16 in (.188 in)

1/4 in (.25 in)

5/16 in (.313 in)

3/8 in (.375 in)

1/2 in (.5 in)

MATERIAL THICKNESS REFERENCE CHART