OM-4433 Page 34

8-6. Adjusting Engine Speed On Standard Models

803 563-E

3

1

2

RPM (Hz)

Engine Speed

(No Load)

Weld/Power

1880 (61.7)

Maximum

Y Stop engine and let cool.
Engine speed is factory set and

should not require adjustment. Af-

ter tuning engine, check engine

speed with tachometer or frequen-

cy meter. See table for proper no

load speed. If necessary, adjust

speed as follows:
Start engine and run until warm.
Turn Process/Contactor switch to

Weld Terminals Always On − Stick

position.
1

Lock Nut

2

Adjustment Screw

Loosen nut. Turn screw until engine

runs at weld/power speed. Tighten

nut.

.

Do not set engine speed higher
than specified. Tampering with

adjustments other than shown

may affect engine warranty

3

Engine Stop Lever

Y Stop engine.
Close door.

Tools Needed: