7. electrical service guide – Miller Electric 383 User Manual

Page 15

Advertising
background image

OM-223 194 Page 11

3-6. Positoning Jumper Links (230/400V 3-Phase Models)

230 V

400 V

3-7. Electrical Service Guide

Migmatic Model

271

273

293

333

383

Input Voltage

230

230

400

230

400

230

400

230

400

Input Amperes at Rated Output

35

23

13

30

18

32

19

38

22

Max Recommended Standard Fuse

or Circuit Breaker Rating in Am-

peres

35

23

13

30

18

32

19

38

22

** Input Conductor Size in mm

2

4

2.5

2.5

6

4

6

4

6

4

** Grounding Conductor Size in

mm

2

4

2.5

2.5

6

4

6

4

6

4

** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters.

Consult national and local regulations.