OM-223 194 Page 18

SECTION 5 − MAINTENANCE &TROUBLESHOOTING

5-1. Routine Maintenance

Y Disconnect power

before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Replace unreadable labels

Repair or replace

cracked weld cable

Clean and tighten weld terminals

6 Months

Blow out or vacuum inside.

OR

Remove drive roll and

carrier. Apply light coat

of oil or grease to drive

motor shaft.

Ref. 802 990

5-2. Circuit Breaker CB1

1

Circuit Breaker CB1

CB1 protects the unit from over-

loading of drive motor M1. If CB1

opens, wire feeding stops.
2

Welding Gun

Check gun liner for blockage or

kinks.
3

Wire Drive Assembly

Check for jammed wire, binding

drive gear or misaligned drive rolls.
Allow cooling period and reset

breaker. Close door.

3

1

2

5-3. Unit Overload

Thermal switches TP1 in XFMR and TP2 in SR1 protect the unit from damage due to overheating. If the thermal indica-

tor illuminates, wait for unit to cool allowing fan motor to run before trying to weld. If unit is cool and no weld output

continues, contact Factory Authorized Service Agent.