9 location of ice machine, Ice machine heat of rejection – Manitowoc Ice S User Manual

Page 21

Advertising
background image

Section 2

Installation Instructions

Part Number 000000966

2-9

Location of Ice Machine

The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.

The location must be free of airborne and other
contaminants.

The air temperature must be at least 35°F (1.6°C),
but must not exceed 110°F (43.4°C).

Remote air cooled - The air temperature must be at
least -20°F (-29°C), but must not exceed 120°F
(49°C)

The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.

The location must not obstruct air flow through or
around the ice machine. Refer to the chart below for
clearance requirements.

Ice Machine Heat of Rejection

Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing
air conditioning equipment where self-contained air-
cooled ice machines are installed.

This information is also necessary when evaluating the
benefits of using water-cooled or remote condensers to
reduce air conditioning loads. The amount of heat added
to an air conditioned environment by an ice machine
using a water-cooled or remote condenser is negligible.

Knowing the amount of heat rejected is also important
when sizing a cooling tower for a water-cooled
condenser. Use the peak figure for sizing the cooling
tower.

S300/S320/S450/S500/

S600/S850/S1000

Self-Contained

Air-Cooled

Water-Cooled

and Remote*

Top/Sides

8" (20.3 cm)

8" (20.3 cm)

Back

5" (12.7 cm)

5" (12.7 cm)

S420

Self-Contained

Air-Cooled

Water-Cooled

and Remote*

Top/Sides

12" (30.5 cm)

8" (20.3 cm)

Back

5" (12.7 cm)

5" (12.7 cm)

S1200

Self-Contained

Air-Cooled

Water-Cooled

and Remote*

Top

8" (20.3 cm)

8" (20.3 cm)

Sides

12" (30.5 cm)

8" (20.3 cm)

Back

5" (12.7 cm)

5" (12.7 cm)

S1400/S1600/S1800

Self-Contained

Air-Cooled

Water-Cooled

and Remote*

Top/Sides

24" (61.0 cm)

8" (20.3 cm)

Back

12" (30.5 cm)

5" (12.7 cm)

*There is no minimum clearance required for water-cooled or remote

ice machines. This value is recommended for efficient operation and
servicing only.

! Caution

The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty. See
“Removal from Service/Winterization”.

Series

Ice Machine

Heat of Rejection

B.T.U./Hour

Air Conditioning

Because the heat of rejection varies during the ice making cycle,

the figure shown is an average.

Peak

S300

5000

6000

S320

3800

6000

S420

5900

6900

S450

5900

6900

S500

6100

6900

S600

9000

13900

S850

13000

16000

S1000

17700

21000

S1200

20700

25400

S1400

25000

28000

S1600

21000

31000

S1800

31000

36000

Advertising