Maintenance
Part Number 000000966
4-3
D. Remove the water trough
•
Depress tabs on right and left side of the water
trough.
•
Allow front of water trough to drop as you pull forward
to disengage the rear pins.
E. Remove the water level probe
•
Pull the water level probe straight down to
disengage.
•
Lower the water level probe until the wiring connector
is visible.
•
Disconnect the wire lead from the water level probe.
•
Remove the water level probe from the ice machine.