Manitowoc Ice S User Manual

Page 49

Advertising
background image

Section 4

Maintenance

Part Number 000000966

4-7

Water Dump Valve

The water dump valve normally does not require
removal for cleaning. To determine if removal is
necessary:

1. Set the toggle switch to ICE.

2. Verify the water trough fills with water at the

beginning of the freeze cycle.

3. While the ice machine is in the freeze mode, check

the water trough to determine if the dump valve is
leaking. If there is no or little water in the water
trough (during the freeze cycle) the dump valve is
leaking.

A. If the dump valve is leaking, remove,

disassemble and clean it.

B. If the dump valve is not leaking, do not remove

it. Instead, follow the “Ice Machine Cleaning
Procedure”.

Follow the procedure below to remove the dump valve.

1. Leaving the wires attached, twist coil and rotate it

counter-clockwise1/4 turn.

2. Lift the coil assembly off the valve body.

3. Remove the spring, plunger, and nylon gasket from

the valve body.

NOTE: At this point, the water dump valve can easily be
cleaned. If complete removal is desired, continue with
step 4.

NOTE: During cleaning, do not stretch or damage the
spring.

4. Remove the tubing from the dump valve by twisting

the clamps off.

5. Twist the valve body to remove from mounting

bracket.

Dump Valve Disassembly

!

Warning

Disconnect the electric power to the ice machine at
the electric service switch box and turn off the water
supply before proceeding.

SPRING

PLUNGER

DIAPHRAM

VALVE BODY

COIL

MOUNTING BRACKET

NYLON GASKET

Advertising