Section 4 − installation, 1. specifications, 2. removing top cover – Miller Electric 15A User Manual

Page 14

Advertising
background image

OM-1213 Page 10

SECTION 4 − INSTALLATION

4-1. Specifications

Wire Diameter

Range

Approximate

Wire Feed

Range

Cooling

Method

Maximum

Spool Size

Weld

Circuit

Rating

IP Rating

Overall

Dimensions

Weight

.025 Thru 1/16 in

(0.6 Thru 1.6 mm)

Aluminum Wire

.025 Thru .045 in

(0.6 Thru 1.1 mm)

Hard Or Cored Wire

70 To 875 ipm

(1.7 To 22.2

mpm)

Air Cooled

4 in (102 mm)

Diameter

100 Volts,

200 Amperes,

100% Duty

Cycle Using

Argon

Shielding Gas

IP 23

Length: 15-3/8 in

(390 mm)

Width: 2-1/2 in

(64 mm)

Height: 10-3/4 in

(273 mm)

2.9 lb

(1.3 kg) Gun

Only

15A Model:

9 lb (4.1 kg)

Gun With Cable

30A Model:

14 lb (6.4 kg)

Gun With Cable

Use weld control or welding power source Owner’s Manual during gun installation.

If contact tip, liner, and drive roll groove are not correct for wire size and type, see

Section 6 to change parts as needed. See Parts List for other available contact

tips.

NOTE

4-2. Removing Top Cover

150 882-G

1

Top Cover Triangular Boss

Push up on triangular boss to open

door. Door hinges on handle.
To open door fully, push up on door

until it clicks into position.

.

If door is pushed too far it will
separate from handle. If this

happens the door can be rein-

stalled.

Push door back into original posi-

tion to close.

1

Advertising
This manual is related to the following products:

30A