OM-1213 Page 13

4-7. Installing Gas Supply

ssb3.1* 5/94 − 158 697-A

Obtain gas cylinder and chain to

running gear, wall, or other station-

ary support so cylinder cannot fall

and break off valve.
1

Cap

2

Cylinder Valve

Remove cap, stand to side of valve,

and open valve slightly. Gas flow

blows dust and dirt from valve.

Close valve.
3

Cylinder

4

Regulator/Flowmeter

Install so face is vertical.
5

Gas Hose Connection

Fitting has 5/8-18 right-hand

threads.
6

Flow Adjust

Typical flow rate is 20 cfh (cubic feet

per hour). Check wire manufactur-

er’s recommended flow rate.
Make sure flow adjust is closed

when opening cylinder to avoid

damage to the flowmeter.
7

CO

2

Adapter

8

O-Ring

Install adapter with O-ring between

regulator/flowmeter and CO

2

cylinder.

Tools Needed:

1-1/8, 5/8 in

CO

2

Gas

7

8

3

1

2

4

5

6

1

2

3

Argon Gas

OR

Advertising
This manual is related to the following products:

30A