Table 11-2, Pmc1 events—mmcr0[19:25] select encodings, Table 11-3 – IBM POWERPC 750GL User Manual

Page 352: Pmc2 events—mmcr0[26:31] select encodings

Advertising
background image


User’s Manual
IBM PowerPC 750GX and 750GL RISC Microprocessor

Performance Monitor and System Related Features

Page 352 of 377

gx_11.fm.(1.2)

March 27, 2006

Software is expected to use the mtspr instruction to explicitly set PMC to nonoverflowed values. Setting an
overflowed value might cause an erroneous exception. For example, if both MMCR0[ENINT] and either
PMC1INTCONTROL or PMCINTCONTROL are set and the mtspr instruction loads an overflow value, an
interrupt signal might be generated without event counting having taken place.

The event to be monitored can be chosen by setting MMCR0[19:31]. The selected events are counted begin-
ning when MMCR0 is set until either MMCR0 is reset or a performance-monitor interrupt is generated.
Table 11-2 lists the selectable events and their encodings.

Bits MMCR0[26:31] specify events associated with PMC2, as shown in Table 11-3.

Table 11-2. PMC1 Events—MMCR0[19:25] Select Encodings

Encoding

Description

000 0000

Register holds current value.

000 0001

Number of processor cycles.

000 0010

Number of instructions that have completed. Does not include folded branches.

0000011

Number of transitions from 0 to 1 of specified bits in the Time Base Lower (TBL) register. Bits are specified through
RTCSELECT, MMCR0[7–8].
00

31

01

23

10

19

11

15

0000100

Number of instructions dispatched—0, 1, or 2 instructions per cycle.

0000101

Number of Enforce In-Order Execution of I/O (eieio) instructions completed.

0000110

Number of cycles spent performing table-search operations for the instruction translation lookaside buffer (ITLB).

0000111

Number of accesses that hit the L2. This event includes cache operations (such as data-cache-block set-to-zero
[dcbz]).

0001000

Number of valid instruction effective addresses (EAs) delivered to the memory subsystem.

0001001

Number of times the address of an instruction being completed matches the address in the Instruction Address
Breakpoint Register (IABR).

0001010

Number of loads that miss the L1 with latencies that exceeded the threshold value.

0001011

Number of branches that are unresolved when processed.

0001100

Number of cycles the dispatcher stalls due to a second unresolved branch in the instruction stream.

All others

Reserved. Might be used in a later revision.

Table 11-3. PMC2 Events—MMCR0[26:31] Select Encodings

(Page 1 of 2)

Encoding

Description

00 0000

Register holds current value.

00 0001

Counts processor cycle.

00 0010

Counts completed instructions. Does not include folded branches.

00 0011

Counts transitions from 0 to 1 of TBL bits specified through MMRC0[RTCSELECT].
00

47

01

51

10

55

11

63

00 0100

Counts instructions dispatched: 0, 1, or 2 instructions per cycle.

Advertising
This manual is related to the following products: