Appendix C — Interfaces
RS-232 Interface
Protocol
Default setup:
Baud rate:
9600
Char. length
8 bits
Parity:
None
Stop bits:
1
RTS/CTS Disabled
ENQ/ACK: Disabled
XON/XOFF:
Disabled (both ways)
New Line:
CR/LF
To change the RS-232 interface settings, see Chapter 6, “Setting Up the
Printer.”
Signals on printer’s serial port:
DB-9
Signal Meaning
1
External +5V DC*
2
TXD
Transmit data
3
RXD
Receive data
4
DSR
Data set ready
5
GND
Ground
6
DTR
Data terminal ready
7
CTS
Clear to send
8
RTS
Request to send
9
–
Not used
*
/. The external +5V is limited to 500 mA and is automatically switched
off at overload.
Interface Cable
Computer end: Depends on computer model