Symptom / Error

FRU / Action in Sequence

111
(I/O parity.)

1. Go to “Memory

Checkout” on
page 128.

2. System board

161
(Dead battery.)

1. Go to “Checking the

Backup Battery” on
page 134.

2. Backup battery
3. System board

163
(Time and date was not
set.)

1. Set time and date

2. System board

173
(Configuration data was
lost.)

1. Select OK in the error

screen; then set the
time and date.

2. Backup battery
3. System board

174
(Configuration error:
Perform“Checking the
Installed Devices List” on
page 152 before changing
any FRUs.)

1. Check device

configuration.

2. Hard disk drive

assembly

3. System board

184
(POP check sum error.)

1. Reset the POP

(power-on password)
in Easy-Setup.

190
(Depleted battery pack was
installed when the power
was on.)

1. Go to “Checking the

Battery Pack” on
page 133.

191XX
(PM initialization error.)

1. System board

195
(The configuration read from
the hibernation area does
not match the actual
configuration.)

1. Check if the

configuration was
changed.
For example, check if
the DIMM card is
added.

196
(Read error occurred in the
hibernation area of the
HDD.)

1. Run the hard disk

drive test.

2. Hard disk drive

1XX

1. System board

ThinkPad 560, 560E (2640)