IBM THINKPAD S05L-1270-01 User Manual

Page 53

Advertising
background image


Symptom / Error

FRU / Action in Sequence

173
(Configuration data was
lost.)

1. Select OK in the error

screen; then set the
time and date.

2. Backup battery
3. System board

174
(Configuration error:
Perform“Checking the
Installed Devices List” on
page 55 before changing
any FRUs.)

1. Check Device

Configuration.

2. Hard disk drive

3. System board

184
(POP check sum error.)

Reset the POP (power-on
password) in Easy-Setup.

190
(Depleted battery pack was
installed when the power
was on.)

Go to “Checking the
Battery Pack” on page 35.

191XX
(PM initialization error.)

System board

195
(The configuration read from
the hibernation area does
not match the actual
configuration.)

Check if the configuration
was changed.
For example, check if the
DIMM is added.

196
(Read error occurred in the
hibernation area of the
HDD.)

1. Run the hard disk

drive test.

2. Hard disk drive

1XX

System board

2XX

201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.

205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.

1. Go to “Memory

Checkout” on
page 30.

2. DIMM
3. System board

301, 303, 304, 305, 3XX
(301: Keyboard error.)

1. Go to

“Keyboard/Auxiliary
Input Device
Checkout” on
page 31.

2. Keyboard
3. External numeric

keypad

4. External keyboard
5. Keyboard/mouse cable
6. Subcard
7. System board

ThinkPad 380, 385 (2635)

41

Advertising