Symptom / Error

FRU / Action in Sequence

602
(Diskette read error.)

1. Go to “Diskette Drive

Checkout” on
page 529.

2. Diskette
3. Diskette drive

604
(An unacceptable ID was
read from the diskette
drive.)

1. Go to “Diskette Drive

Checkout” on
page 529.

2. Diskette drive
3. System board

11XX
1101: Serial_A test failure.

1. Serial device

2. Communication cable
3. System board

17XX

1701: Hard disk controller
failure.
1780, 1790: Hard disk 0
error.
1781, 1791: Hard disk 1
error.

1. Hard disk drive

2. System board

24XX
(2401: System board video
error.)

1. System board
2. Video card

808X

8081: Presence test failure.
(PCMCIA revision number
also checked.)
8082: PCMCIA register test
failure.

1. PCMCIA slot

assembly

2. PCMCIA device
3. System board

4. PC Card in docking

station/PC Card
enabler

860X
(Pointing device error when
TrackPoint III is disabled.)

8601: System bus
error—8042 mouse
interface.
8602: External mouse error.
8603: System bus or mouse
error.

1. External mouse
2. External keyboard
3. System board

861X
(Pointing device error when
TrackPoint III is enabled.)

8611: System bus
error—I/F between 8042
and IPDC.
8612: TrackPoint error.
8613: System board or
TrackPoint error.

1. Reseat the keyboard

connector on the
video card.

2. Reseat the TrackPoint

III cable on the
keyboard card.

3. Keyboard
4. External mouse
5. Video card
6. System board

ThinkPad 770 (9548, 9549)