Checking the battery pack – IBM THINKPAD S05L-1270-01 User Manual

Page 436

Advertising
background image

Checking the Battery Pack:

Battery charging will

not start until the Fuel-Gauge shows that less than 95% of
the total power remains; with this condition the battery
pack will charge to 100% of its capacity. This protects the
battery pack from being overcharged or having a
shortened life.

Do the following:

1. Power off the computer.
2. Remove the battery pack and measure the voltage

between battery terminals 1 (

+

) and 4 (

). See the

following figure:

Note: Signal lines not used in these steps are used

for communication between the system and
the battery.

3. If the voltage is less than

+

11.0 V dc, the battery pack

has been discharged. Recharge the battery pack.

If the voltage is still less than

+

11.0 V dc after

recharging, replace the battery.

Note: If the voltage of the battery pack is 0 V, it is

defective.

4. If the voltage is more than

+

11.0 V dc, measure the

resistance between battery terminals 3 and 4. The
resistance must be 4 to 30 K ohm.

If the resistance is not correct, replace the battery
pack.

If the resistance is correct, replace the DC/DC card.

Terminal

Voltage (V dc) / Signal

1

+

0 to

+

13.5

2

Send

3

Thermal

4

Ground (

)

5

Select

424

IBM Mobile Systems HMM